Facilities And Procedures Used For The Performance Testing Of Doe Personnel Dosimetry Systems Book in PDF, ePub and Kindle version is available to download in english. Read online anytime anywhere directly from your device. Click on the download button below to get a free pdf file of Facilities And Procedures Used For The Performance Testing Of Doe Personnel Dosimetry Systems book. This book definitely worth reading, it is an incredibly well-written.

Facilities and Procedures Used for the Performance Testing of DOE Personnel Dosimetry Systems

Author :
Publisher :
Page : pages
File Size : 33,56 MB
Release : 1983
Category :
ISBN :

GET BOOK

Radiological calibration facilities for personnel dosimeter testing were developed at the Pacific Northwest Laboratory (PNL) for the Department of Energy (DOE) to provide a capability for evaluating the performance of DOE personnel dosimetry systems. This report includes the testing methodology used. The informational presented here meets requirements specified in draft ANSI N13.11 for the testing laboratory. The capabilities of these facilities include sealed source irradiations for 137Cs, several beta-particle emitters, 252Cf, and machine-generated x-ray beams. The x-ray beam capabilities include filtered techniques maintained by the National Bureau of Standards (NBS) and K-fluorescent techniques. The calibration techniques, dosimeter irradiation procedures, and dose-equivalent calculation methods follow techniques specified by draft ANSI N13.11 where appropriate.

Department of Energy Standard for the Performance Testing of Personnel Dosimetry Systems

Author :
Publisher :
Page : pages
File Size : 12,84 MB
Release : 1986
Category :
ISBN :

GET BOOK

This standard is intended to be used in the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems. It is based on the American National Standards Institute's (ANSI) ''Criteria for Testing Personnel Dosimetry Performance, '' ANSI N13.11-1983, recommendations made to DOE in ''Guidelines for the Calibration of Personnel Dosimeters, '' Pacific Northwest Laboratory (PNL)-4515 and comments received during peer review by DOE and DOE contractor personnel. The recommendations contained in PNL-4515 were based on an evaluation of ANSI N13.11 conducted for the Office of Nuclear Safety, DOE, by PNL. Parts of ANSI N13.11 that did not require modification were used essentially intact in this standard to maintain consistency with nationally recognized standards. Modifications to this standard have resulted from several DOE/DOE contractor reviews and a pilot testing session. An initial peer review by selected DOE and DOE contractor representatives on technical content was conducted in 1983. A review by DOE field offices, program offices, and contractors was conducted in mid-1984. A pilot performance testing session sponsored by the Office of Nuclear Safety was conducted in early 1985 by the Radiological and Environmental Sciences Laboratory, Idaho Falls. Results of the pilot test were reviewed in late 1985 by a DOE and DOE contractor committee. 11 refs., 4 tabs.

Handbook for the Department of Energy Laboratory Accreditation Program for Personnel Dosimetry Systems

Author :
Publisher :
Page : pages
File Size : 26,23 MB
Release : 1986
Category :
ISBN :

GET BOOK

The program contained in this Handbook provides a significant advance in the field of radiation protection through a structured means for assuring the quality of personnel dosimetry performance. Since personnel dosimetry performance is directly related to the assurance of worker safety, it has been of key interest to the Department of Energy. Studies conducted over the past three decades have clearly demonstrated a need for personnel dosimetry performance criteria, related testing programs, and improvements in dosimetry technology. In responding to these needs, the DOE Office of Nuclear Safety (EH) has developed and initiated a DOE Laboratory Accreditation Program (DOELAP) which is intended to improve the quality of personnel dosimetry through (1) performance testing, (2) dosimetry and calibration intercomparisons, and (3) applied research. In the interest of improving dosimetry technology, the DOE Laboratory Accreditation Program (DOELAP) is also designed to encourage cooperation and technical interchange between DOE laboratories. Dosimetry intercomparison programs have been scheduled which include the use of transport standard instruments, transport standard radioactive sources and special dosimeters. The dosimeters used in the intercomparison program are designed to obtain optimum data on the comparison of dosimetry calibration methodologies and capabilities. This data is used in part to develop enhanced calibration protocols. In the interest of overall calibration update, assistance and guidance for the calibration of personnel dosimeters is available through the DOELAP support laboratories. 20 refs., 1 tab.

Performance Comparisons of Selected Personnel-dosimetry Systems in Use at Department of Energy Facilities

Author :
Publisher :
Page : pages
File Size : 46,78 MB
Release : 1983
Category :
ISBN :

GET BOOK

Dosimeter performance data were collected to help develop a uniform approach to the calibration and use of personnel dosimetry systems for Department of Energy (DOE) laboratories. Eleven DOE laboratories participated in six months of testing using the American National Draft Standard, Criteria for Testing Personnel Dosimetry Performance, ANSI N13.11, and additional testing categories. The tests described in ANSI N13.11 used a pass/fail system to determine compliance with the draft standard. Recalculation to PNL irradiations showed that the 137Cs, 9°Sr/9°Y, and 252Cf categories can be recalibrated to have acceptable performance for nearly all participant systems. Deficient dosimeter design or handling techniques caused poor performance in the x-ray category for nearly half of the participants. Too little filtration for the deep-dose element caused poor performance in the beta/photon mixture category for one participant. Two participants had excessively high standard deviations in the neutron category due to dosimeter design or handling deficiencies. The participating dosimetry systems were separated into three categories on their dose evaluation procedure for low-energy photons. These were film dosimeters, fixed-calibration thermoluminescent (TL) dosimeters, and variable-calibration TL dosimeters. The performance of the variable-calibration design was best while the film dosimeters performed considerably worse than either TL dosimeter design. Beta energy dependence studies confirmed a strong correlation between sensitive element thickness, shallow element filtration and low-energy beta response. Studies of neutron calibration conditions for each participant suggested a relationship between response and calibration facility design.

Techniques and Management of Personnel Thermoluminescence Dosimetry Services

Author : M. Oberhofer
Publisher : Springer Science & Business Media
Page : 462 pages
File Size : 39,69 MB
Release : 1993-10-31
Category : Medical
ISBN : 9780792324362

GET BOOK

The International Commission on Radiological Protection and the Euratom Council directive have specified that workers exposed to ionizing radiation shall be subjected to individual dose monitoring. In the past, individual doses have almost always been monitored by film badge dosimeters, but thermoluminescent dosimeters (TLDs) are now coming into widespread use, principally due to the availability of automated readout systems. Techniques and Management of Personnel Thermoluminescence Dosimetry Services gives details of the operation of and experience gained with a number of large-scale TL personnel dosimetry services, with particular attention being paid to the management aspects of such services. For technical and administrative personnel in TLD services, TLD system designers, staff of licensing authorities concerned with dosimetric licensing, students of radiation protection, especially in the area of protection from ionizing radiation. A basic knowledge of atomic and nuclear physics is assumed, and a training in radiation protection or health physics would be an advantage.